Riello Sentinel Dual UPS SDU 6000 A7 PDIST 6000W 6kVA 8x C13 2x C19 32A 3U 240V

EUR 584,84 Compralo Subito, EUR 187,15 Spedizione, 30-Giorno Restituzione, Garanzia cliente eBay
Venditore: itinstock ✉️ (28.408) 100%, Luogo in cui si trova l'oggetto: London, GB, Spedizione verso: GB, EUROPEAN_UNION, Numero oggetto: 404125902416 Riello Sentinel Dual UPS SDU 6000 A7 PDIST 6000W 6kVA 8x C13 2x C19 32A 3U 240V.
  • Riello Sentinel Dual UPS SDU 6000 A7 PDIST 6000W 6kVA 8x C13 2x C19 32A 3U 240V
Model: Sentinel Dual UPS SDU 6000 A7 PDIST P/N: CSDU6K0AA7U0RUA In Good Condition And  Full Working Order Tested   Supplied With batteries, Rack Rails + Tower Feet Included
  • 1 x Riello Sentinel Dual UPS SDU 6000 A7 PDIST 6000W 6kVA 8x C13 2x C19 32A 3U 240V
  • Batteries
  • 1 x Power Cable
Overview
  • Sentinel Dual is the best solution for powering mission critical applications and  electro-medical devices requiring maximum  power reliability.
  • Flexibility of installation and use (digital  display, user-replaceable battery set), as well  as the many communication options available,  makes the Sentinel Dual suitable for many  different applications from IT to security. 
  • Up to 3 Sentinel Dual can be operated in  parallel in either capacity or N+1 redundant  configuration offering increased reliability  for critical system. 
  • The Sentinel Dual can be  installed as Tower (floor standing) or Rack,  ideal for network and server rack applications. 
  • The Sentinel Dual range is available in 4 kVA  and 5-6-8-10 kVA/kW models with on-line  double conversion technology (VFI): the load  is powered continuously by the inverter  which supplies a sinusoidal voltage, filtered  and stabilised in terms of voltage, form  and frequency. In addition, the input and  output filters significantly increase the load’s  immunity to mains disturbances and lightning  strikes. 
  • Technology and performance: selectable  Eco Mode and Smart Active Mode functions.  Diagnostics: Standard digital display, RS232  and USB interfaces with PowerShield  software downloadable, communications slot  for connectivity accessories. 
Simplified installation
  • Can be installed on the floor (tower version)  or in rack mount cabinets (rack version). The  display panel can be rotated (using the key  supplied).
  • Low noise (<45 dBA): can be installed  in any environment thanks to its high  frequency switching inverter and PWM  load-dependent digitally controlled fan
  • External bypass option for maintenance  with interruption-free switching
  • Operation guaranteed up to 40°C (the  components are designed for high  temperatures and are thus subject to less  stress at normal temperatures)
  • Built-in IEC output sockets with thermal protection.
Operating mode selection
  • Functions can be programmed via software or  manually via the front display panel.
  • On line: efficiency up to 95%
  • Eco Mode: to increase efficiency (up to  to 98%), allows for the selection of Line  Interactive technology (VI) to power low  priority loads from the mains supply
  • Smart Active: the UPS automatically  decides upon the operating mode (VI or VFI)  based on the quality of the mains power  supply
  • Emergency: the UPS can be selected to  function only when the mains power supply  fails (emergency only mode).
  • Frequency converter operation (50 or  60 Hz).
High quality output voltage
  • Even with non-linear loads (IT loads with a crest factor of up to 3:1)
  • High short circuit current on bypass
  • High overload capacity: 150% by inverter  (even with mains failure)
  • Filtered, stabilised and reliable voltage (double conversion on-line technology  (VFI compliant with EN62040-3), with  filters for the suppression of atmospheric  disturbances.
  • Power factor correction: UPS input power factor close to 1 and sinusoidal current  uptake.
High battery reliability
  • Automatic and manual battery test
  • Reduced ripple component (detrimental to the batteries) using a low ripple current  discharge (LCRD) system
  • Batteries are user replaceable without switching off equipment and without  interruption to the load (Hot Swap)
  • Unlimited extendible runtime using matching Battery Boxes
  • The batteries do not cut in during mains failures of <20 ms (high hold up time) or  when the 
Emergency function This configuration ensures the operation of those emergency systems that require  continuous, reliable and long-lasting power  supply in the event of a mains power failure,  such as emergency lighting, fire detection/  extinguishing systems and alarms. When the  mains power supply fails, the inverter begins  powering the loads with a progressive startup (Soft Start) in order to prevent overload. Battery optimisation The wide input voltage range and a high holdup time minimise battery usage and increase efficiency and battery life; for smaller power  breaks, energy is drawn from a group of  appropriately-sized capacitors. Runtime expandability Optional battery extension packs can be connected to increase UPS runtime. In  addition the Sentinel Dual range includes ER  versions with no internal batteries and more  powerful battery chargers for longer runtimes. EnergyShare 10 A configurable IEC output sockets allow for runtime optimisation by programming the  switching off of low priority loads on mains  failure; alternatively, emergency loads that  are normally not powered when mains is  present can be activated. Other features
  • Selectable output voltage (220-230-240 V)
  • Dual input supplies configuration (SDU 10000 DI and SDU 10000 DI ER)
  • Auto-restart when mains power is restored (programmable via software)
  • Bypass on: when the machine is switched off, it automatically goes into bypass and  battery charge mode
  • Minimum load switch-off
  • Low battery warning
  • Start-up delay
  • Total microprocessor and DSP control
  • Automatic bypass without interruption
  • Use of custom power modules
  • Status, measurements and alarms available on standard backlit display
  • UPS digital updating (flash memory upgradeable)
  • Output sockets protected with resettable thermal switch
  • Back-feed protection standard: to prevent energy from being fed back to the network
  • Manual switching to bypass.
Advanced communications
  • Advanced multi-platform communications  for all operating systems and network  environments: PowerShield3 monitoring and  shutdown software for Windows operating  systems 10, 8, 7, Hyper-V, 2019, 2016,  2012, and previous versions, Mac OS X,  Linux, VMWare ESXi, Citrix XenServer and  other Unix operating systems
  • Plug and play function
  • USB port
  • RS232 serial port
  • Slot for installation of communications  boards.
Unity Power Factor
  • More power delivered
  • More real output power (W)
Specification: INPUT
  • Dual Input: no
  • Rated power: 6000 VA
  • Voltage: 220 / 230 / 240 V
  • Voltage tolerance: 230 V ±20% full load / 230 V +20% -40% half load
  • Frequency: 50 / 60 Hz ±5
  • Power factor: >0.98
  • Current distorsion: ≤2%
BY PASS
  • Voltage tolerance: 180 / 264 V (selectable in ECO Mode or SMART ACTIVE Mode)
  • Frequency tolerance Selected frequency: ±5% (selectable by user)
OUTPUT and INVERTER OUTPUT
  • Rated power: 6000 VA
  • Active power: 6000 W
  • Crest factor (Ipeak/Irms): 3 : 1
  • Waveform: Sinusoidal
  • Frequency: 50 / 60 Hz selectable
  • Voltage distortion with nonlinear load:  <3%
  • Voltage distortion with  linear load:  <1%
BATTERIES
  • Type: VRLA AGM maintenance-free lead based
  • Typical recharge time: 4-6 h
ENVIRONMENTAL
  • Color: Black RAL 9005
  • Communication: USB / RS232 / slot for communications interface / REPO + Input contact
  • Protections: Overcurrent - short circuit - overvoltage - undervoltage - temperature - excessive low battery
  • Noise (at 1 m): <48 [bBA] (ECO Mode)
  • Operating temperature: 0 °C - +40 °C
  • Relative humidity: 5-95% non-condensing
  • Output sockets: Terminal block + 2 IEC 320 C13 - PDIST / ER: Terminal block + 8 IEC 320 C13 + 2 IEC 320 C19
  • Standards:  European directives: L V 2014/35/EU low voltage; EMC 2014/30/EU electromagnetic compatibility -- Standards: Safety IEC EN 62040-1; EMC IEC EN 62040-2; RoHS compliant -- Classification in  accordance with IEC 62040-3 VFI - SS - 111
DATA
  • Weight: 46 kg
  • Dimensions (h w d): 448x131x640 Tower - 3Ux19”x640 Rack mm
  • Input phases: 1
  • Output phases: 1
VAT @ 20% INCLUDED IN PRICE - VAT INVOICE PROVIDED £500 excluding VAT VAT IS NOT PAYABLE BY PURCHASERS OUTSIDE OF THE UK LJM 289523 289524 289525 289526 289527 289529 289530 289531 289532 289533 289534 289535 289536 289528 - Ready to go 22/01 + rails tk frm 292018 + stand tk frm 289539 -14
  • Condition: Usato
  • Condition: In Good Condition And Full Working Order, Tested.
  • Compatible Brand: Riello
  • Voltage Compatibility: 220V, 230 V, 240V, 6000 VA
  • MPN: SDU6000, SDU 6000, SDU 6000 A7, SDU 6000 A7 PDIST, PDIST, CSDU6K0AA7U0RUA, Tower, Rack
  • Item Length: 640MM, 64CM
  • Topology: Line interactive
  • Waveform Type:: Sinusoidal
  • Colour: Black
  • Brand: APC
  • Connectors: C13, C19, Terminal, Terminal Block
  • Type: Tower / Rackmount
  • Maximum Wattage: 6000 W
  • Maximum Power: 6000 W
  • Item Height: 448MM, 44.8CM
  • Model: SDU 6000
  • Number of Outlets: 10
  • Output Connections:: 8 x power IEC C13 2 x power IEC C19, Terminal Block
  • Features: Rack Mountable, Tower, 6KVA
  • Input Connection type:: IEC 309 32A
  • Item Width: 131MM, 13.1CM
  • Typical Recharge Time:: 4 - 6 Hours