Ports
|
48 10/100 ports (IEEE
802.3 Type 10Base-T,
IEEE 802.3u Type
100Base-TX)
|
2 dual-personality
ports-each port can be
used as either an RJ-45
10/100/1000 port (IEEE
802.3 Type 10Base-T;
802.3u Type 100Base-TX;
802.3ab 1000Base-T
Gigabit Ethernet) or an
open mini-GBIC slot (for
use with mini-GBIC
transceivers)
1 RS-232C DB-9 console
port
|
|
Physical characteristics
|
Dimensions
|
12.8 x 17.32 x 1.75 in.
(32.51 x 43.99 x 4.45
cm) (1U height)
|
Weight (fully
loaded)
|
9.78 lb. (4.4 kg)
|
|
Memory and processor
|
Flash capacity
|
8 MB
|
|
|
Processor type and speed
|
Motorola PowerPC MPC8245
@ 266 MHz
|
|
|
Flash capacity
|
8 MB
|
|
|
SDRAM
|
32 MB
|
|
Mounting
|
Mounts in an
EIA-standard 19 in.
telco rack or equipment
cabinet (hardware
included); horizontal
surface mounting only
|
|
Performance
|
Latency
|
<13.3 µs (LIFO)
|
Throughput
|
Up to 10.1 million pps
|
Routing/Switching
capacity
|
13.6 Gbps
|
Routing table size
|
8,000 entries
|
|
Environment
|
Operating temperature
|
32° to 131°F (0° to
55°C)
|
Operating relative
humidity
|
15% to 95% @ 104°F
(40°C), non-condensing
|
Non-operating/
Storage temperature
|
–40° to 158°F (–40° to
70°C)
|
Non-operating/
Storage relative
humidity
|
15% to 95% @ 149°F
(65°C), non-condensing
|
Alitude
|
Up to 15,091 ft. (4.6
km)
|
|
Electrical
characteristics
|
Maximum BTUs
|
341 BTU/hr
|
Voltage
|
100–120 VAC/200–240 VAC
|
Current
|
1.5A
|
Power consumption
|
100W
|
Frequency
|
50/60 Hz
|
|
Safety
|
CSA 22.2 No. 950; cUL
(CSA 950); EN 60950/IEC
60950;
NOM-019-SCFI-1994; UL
1950 3rd edition; UL
60950
|
|
Emissions
|
FCC Class A;
EN55022/CISPR-22 Class
A; VCCI Class A
|
|
Immunity
|
Generic
|
EN55024/CISPR 24
|
EN
|
EN55024/CISPR 24
|
ESD
|
IEC 61000-4-2, 4 kV CD,
8 kV AD
|
Radiated
|
IEC 61000-4-3, 3V/m
|
EFT/Burst
|
IEC 61000-4-4, 1.0 kV (power
line), 0.5 kV (signal
line)
|
Surge
|
IEC 61000-4-5, 1 kV/2 kV
AC
|
Conducted
|
IEC 61000-4-6, 3V
|
Power frequency
magnetic field
|
IEC 61000-4-8, 1A/m, 50
or 60 Hz
|
Voltage dips and
interruptions
|
IEC 61000-4-11, >95%
reduction, 0.5 period;
30% reduction, 25
periods
|
Harmonics
|
EN 61000-3-2/IEC
61000-3-2
|
Flicker
|
EN 61000-3-3/IEC
61000-3-3
|
|
Management
|
ProCurve Manager (included);
ProCurve Manager Plus;
command-line interface;
Web browser;
configuration menu;
out-of-band management (serial
RS-232C)
|
|
Standards and protocols
|
RFC 783 TFTP; RFC 951
BootP; RFC 1542 BootP;
RFC 854 Telnet; RFC 768
UDP; RFC 792 ICMP; RFC
793 TCP; RFC 826 ARP;
RFC 2030 SNTP; IEEE
802.3X Flow Control; RFC
2236 IGMPv1/v2/v3; IEEE
802.1D Spanning Tree;
IEEE 802.1w Rapid
Convergence Spanning
Tree; IEEE 802.3ad Link
Aggregation Control
Protocol; IEEE 802.3af
Power over Ethernet;
IEEE 802.1Q GVRP; RFC
1492 TACACST; SSHv1/v2
Secure Shell; Secure
Sockets Layer (SSL);
IEEE 802.1X Network
Login; IEEE 802.1p
Priority; SNMPv1/v2c/v3;
HTML and telnet
management; RFC 1493
Bridge MIB; RFC 1213 MIB
II; RFC 2096 IP
Forwarding Table MIB;
RFC 2737 Entity MIB; RFC
2863 Evolution of
Interface; RFC 2665
Ethernet MIB; RFC 2819
Four groups of RMON: 1 (statistics),
2 (history), 3 (alarm),
and 9 (events); RFC 2021
RMON probe configuration
(RMON v2); RFC 2668
802.3 MAU MIB; RFC 2613
SMON; RFC 2674 802.1p
and IEEE 802.1Q Bridge
MIB; RFC 2618 RADIUS
Client MIB
|